Spec name: |
Description: |
Pipe Diameter (Recommended) |
SE16A: 15 mm to 40 mm (0.5 in to 1.5 in) SE16B: 50 mm to 250 mm (2 in to 10 in) SE16C: 300 mm to 1,200 mm (12 in to 48 in) |
Pipe Diameter (Suitable For) |
SE16A: 15 mm to 150 mm (0.5 in to 6 in) SE16B: 50 mm to 1,200 mm (2 in to 48 in) SE16C: 100 mm to 1,200 mm (4 in to 48 in) |
Pipe Materials |
Any metal or plastic sonic conducting material including carbon steel, stainless steel, ductile iron, concrete-lined ductile iron, cast iron, PVC, HDPE, PVDF, fiberglass, copper, brass, aluminum, and pipes with bonded liners including epoxy, rubber, and Teflon |
Operating Frequency |
SE16A: 2.56 MHz SE16B: 1.28 MHz SE16C: 640 kHz |
Operating Temperature |
-40 °C to 150 °C (-40 °F to 300 °F) |
Transducer Mounting Kit |
SE16A: Includes stainless steel track with pipe clamps, built-in ruler, and coupling tape SE16B: Includes a set of stainless steel transducer brackets, clamps, alignment bar, and coupling tape SE16C: Includes set of stainless steel transducer brackets, clamps, alignment bar with a built-in ruler, and coupling tape |
Transducer Cables |
Triaxial, 7.6 m (25 ft) with BNC connectors and seal jackets; extendable up to 152.4 m (500 ft) |
Hazardous Locations |
Non-incendive for Class I, Div 2, Groups A, B, C, D Optional: Intrinsically safe for Class I, Div 1, Groups C, D; Class II, Groups E, F, G; Class III; Encl. Type 4 |